Description

115/230VAC POWER SUPPLIES

AD SERIES

MAINS POWER SUPPLIES IN 12V, 24V & 48V CONFIGURATIONS

The AD Series units may be used to supply mobile radios and other appliances from?AC mains used in offices, portable site cabins, communication cabins, telephone?exchanges, remote antennae sites, ships, oil rigs etc. The units will accept either?European 230Vac or US 115Vac inputs and are available as standard in 12V, 24V and?48V output configurations.?Input is via a standard IEC-320 C13/14 power cord with?UK, European or US mains plugs -?please state your requirement.

FAST INSTALLATION

There?s nothing worse than a power?supply lying around on the floor. The?T-shaped mounting clip, common to?many Alfatronix products, allows the?power supplies to be installed quickly?and simply in many out of the way?locations, such as underneath desks or?on walls. The 3 point ?T? clip can be?fitted securely, even on uneven surfaces,

quickly and simply, and then the power?supply simply ?clips? in place.

BATTERY CHARGING REQUIRED?

A fixed voltage battery charging facility?is also available with the supplementary?loom; P/N AD BB loom.

FULL CIRCUIT PROTECTION

The AD Series supplies have transient,?overload and overheat protection for?reliable operation even in the toughest?environments.

RUGGED AND COMPACT

These units, often referred to as ?brick?in the lead? supplies are housed in a?rugged, corrosion resistant anodised aluminium extrusion. The low mass

surface mount technology components?offer excellent resistance to shock and?vibration, thus further increasing the?reliability of these products.

?

A green LED indicates when there is?output from the converter. This gives?reassurance to the installation engineer?and speeds fault finding.

DESKTOP VERSIONS ALSO AVAILABLE

While the brick power supplies offer a?versatile solution, if you are powering a?mobile radio, try our Desktop Versions. These are configured?to attach to the radio forming one?dedicated unit and are available for a?variety of radios including Motorola,

Hytera, Tait, Kenwood, Icom, Maxon?and Vertex.

PRODUCT CODING

The product code is developed as follows taking the AD 115/230-12 108 as an example:

AD AC input and DC output
115/230 Denotes auto select US or European AC input voltage
-12 Nominal 12V output
108 108W capacity unit

 

 

Technical Data

 

Input voltage range Auto-Select, 85-135Vac and 170-265Vac, 50/60Hz
Output voltage 13.6Vdc, 27.2Vdc or 54.4Vdc, as ordered . Worst case limits are +/- 4%
Output noise <50mV pk-pk at continuous load
Power Conversion Efficiency Typically 85%
Isolation between input and case/output Isolation casework to ground 1.5kVac/3.0kVac rms,

Connected directly to mains input ground

Normal operating temperature -25?C to +30?C to meet this specification table

+30?C to +70?C de-rate linearly to 0A

Storage Temperature -25?C to +100?C
Max case temperature 70?C at full load with 25?C ambient
Operating humidity 95% max, non-condensing
Casework Anodized aluminium, glass-filled polycarbonate
Connections:

Input

Output

Ground

IEC-320 C14 socket, C13 terminated cordset

6.3mm push-on blade terminals

6.3mm push-on blade terminals, adjacent to input (additional external ground if required)

Output Indicator Green LED adjacent to output terminals
Mounting Method ?Click ?n? Fit? mounting clip or rubber feet. DIN rails clips available required
Safe area protection:

Over Current

Limited by current sensing circuit
Over heat Limited by temperature sensing circuit
Output over voltage Protected by independent shut down circuit
Transients Protected by filters and rugged component selection
Catastrophic failure Protected by input and output fuses
Approvals 2014/30/EU The general EMC directive

2014/35/EU The low voltage directive

93/68/EEC The CE marking directive

Tested to EN60950, EN55022, EN61204-3
Markings CE

 

View The Company Page HERE

View Our LinkedIn Page HERE

Additional information

Manufacture

AlfaTronix

Input voltage range

Auto-Select, 85-135Vac and 170-265Vac, 50/60Hz

Output voltage

12V

Output noise

<50mV pk-pk at continuous load

Power Conversion Efficiency

Typically 85%

Isolation between input and case/output Isolation casework to ground

1.5kVac/3.0kVac rms, Connected directly to mains input ground

Normal operating temperature

-25?C to +30?C to meet this specification table +30?C to +70?C de-rate linearly to 0A

Storage Temperature

-25?C to +100?C

Max case temperature

70?C at full load with 25?C ambient

Operating humidity

95% max, non-condensing

Casework

Anodized aluminium, glass-filled polycarbonate

Connections: Input Output Ground

IEC-320 C14 socket, C13 terminated cordset 6.3mm push-on blade terminals 6.3mm push-on blade terminals, adjacent to input (additional external ground if required)

Output Indicator

Green LED adjacent to output terminals

Mounting Method

?Click ?n? Fit? mounting clip or rubber feet. DIN rails clips available required

Safe area protection: Over Current

Limited by current sensing circuit

Over heat

Limited by temperature sensing circuit

Output over voltage

Protected by independent shut down circuit

Transients

Protected by filters and rugged component selection

Catastrophic failure

Protected by input and output fuses

Approvals

2014/30/EU The general EMC directive 2014/35/EU The low voltage directive 93/68/EEC The CE marking directive

Tested to

EN60950, EN55022, EN61204-3

Markings

CE

Amp

3A

Power Supply Type

AC-DC

AD115/230-12-036 (3A) Mains PS, Desktop Ver, Battery Chargers & LVDs 12V (3A)

Request Price For Large Quantities  Info For Out Of Stock Products Anything Else

Delivery & VAT

 

Delivery

Israel – 14 days – 21 days

WorldWide – 21 days – 40 days

VAT 

Israel – +17%

Payment Method

PayPal

Shipping Cost

Israel – 7.9$

Worldwide – 100$

Fee

10$ Fee if your cart total is below 10$